What is reverse osmosis? Analysis of harm and benefit. Reverse osmosis: design diagram and detailed installation.

Reverse osmosis is one of the most effective ways to purify tap water today. All eminent manufacturers of filter systems, such as Aquaphor, Geyser or Atoll, have already adopted this technology. Consumers are left to buy a suitable kit and deal with the installation instructions.

The principle of operation and features of reverse osmosis

The process of reverse osmosis is nothing more than desalination, that is, the reduction of the content of impurities in the liquid. Previously, it was used to transform sea ​​water into a drinkable one, today the same thing has to be done with tap water. The efficiency of modern household system reverse osmosis exceeds 99%, that is, the quality of the product at the outlet is close to the distillate. How does this happen?


In osmotic filters of any manufacturer (Geyser, Aquaphor, Atoll) one cleaning method is used - forcing the flow through a semi-permeable membrane. It got its name due to the fact that it passes through the smallest pores only H 2 O molecules, oxygen, and even a few elements that turned out to be less than 1 10 -4 microns, leaving other impurities on the reverse side.

Demineralized water, after passing through the cartridges and the osmotic purification membrane, is practically harmless, but there is no benefit from it either. To increase its value and taste, it is better to buy a system with a built-in mineralizer.

For effective work membranes, the liquid must be carefully prepared by removing mechanical suspensions and salts from it, which can be neutralized more in a simple way. Step cleaning requires the use of several cartridges at once, so a single installation of a reverse osmosis filter is not performed. The finished system comes already in a compactly formed kit and is easily mounted even under the kitchen sink.


Popular brands of cleaning systems

Geyser

It produces osmotic cleaning systems as part of the Prestige series. Some of them already come with a mineralizer and a separate faucet in order to receive both absolutely pure and enriched water from one spout. Also included is a storage tank. Thanks to him, you do not need to wait until the flow passes through all the cartridges, but you can immediately draw drinking water.

Geyser Prestige Models:

  • Basic equipment

Step system with mechanical and sorption carbon filters, as well as a tank of 7.6 or 12 liters. Price 8-8.5 thousand rubles.

  • Geyser Prestige-2

Compact model with only two cartridges. Sorption retains mechanical impurities, “traps” dissolved iron and softens water. The second stage of purification is the osmotic membrane. The price is about 5 thousand.

  • Geyser Prestige P

The circuit includes a pump that increases the flow pressure to standard 3 atm when passing through the osmotic membrane. You can buy an improved kit for 11-12 thousand rubles.


  • Geyser Prestige M

Reverse osmosis system with mineralization. Pre-cleaning cartridges remove mechanical suspensions and chlorine compounds, and the mineralizer enriches the water thanks to calcite and magnetite. The kit comes with a standard tank and a two-gang tap for switching filter modes. The price is about 9 thousand.

  • Geyser Prestige PM

The model is completed with both a pumping pump and a mineralizer. You can buy it for 12000-13000 rubles.

Aquaphor

One of the leading manufacturers of domestic water treatment systems also did not ignore reverse osmosis and offered a number of effective solutions. Moreover, the base, as a rule, comes with one - Aquaphor DWM-101S Morion, but cartridge sets can be changed entirely. It is noteworthy that these systems, when compared with the Geyser Prestige discussed above, are able to work effectively even at reduced pressure without a pump. The minimum pressure for most Aquaphor cartridges is 1.5 atm, for which they have already received a lot good reviews from the residents of the upper floors.


You can buy replacement filter sets for Morion:

  • Aquaphor DWM-31 - a set with a softening cartridge and a mineralizer purifies water at a rate of 15-16 l / h. Price - up to 5 thousand rubles.
  • Aquaphor Osmo-50 - productivity 7-8 l / h at a pressure of 3.5 atm. Depending on the performance, it can be bought for 5-8 thousand.
  • Aquaphor Osmo-Crystal 100 is an analogue of DWM-31, but already at a higher price from 6 to 8 thousand rubles.

Aquaphor Morion models are equipped with a 5-liter storage tank built into the body. This simplifies installation under the sink, and also saves a lot of usable space in the cabinet. This design is worth buying if you don’t have much space in the kitchen, but you still want to get safe drinking water in non-stop mode. Aquaphor systems are also suitable for those who have a flow meter installed on their pipes. While Geyser Prestige or Atoll spend about 60% of the total volume of water on the removal of contaminants from the membrane, 20% is enough for Morion-type structures.

Atoll

The Atoll reverse osmosis system can be supplied both in the usual form of a set of cartridges with a storage tank, and in the form finished block. The latter, according to reviews, is best suited for self-installation.


Main series:

  • A-550 STD

Standard 5-stage under-sink filter. Unlike the same Geyser Prestige, it is able to operate at a pressure in the pipeline of 2.8-6.0 atm. Models marked "p" are equipped with a pump - they are worth buying if the pressure characteristics of the flow do not exceed the lower threshold of 2.8 atm. The price is 11900 rubles.

  • A-450 STD

Budget option with the possibility of selecting a complete set. The number of simultaneously installed cartridges is 4-5 pieces, the osmotic membrane is two- or three-layer. Base price 9600 rubles. A little more expensive will be the Compact modification with an eight-liter tank and 4 cartridges. Mineralizers are equipped with sets with the designation "m", but the price of this increases by only 400-500 rubles.

  • SailBoat (aka Box)

Essentially the same set of replaceable cartridges with a storage tank, but compactly packed into an elegant case. Instead of a post-filter, a mineralizer is optionally installed to improve palatability water. You can buy Atoll Box at a price of 17 thousand rubles, models with pomp in this group of goods will cost about 22.5 thousand.


  • A-5400ep

Ready-to-sink unit with filter status indicators. In the basic configuration there is a pump that allows you to use cleaning at low pressure in the pipes (0.7-2.8 atm). Fully automated scheme of work, all information is displayed on the display panel of the electronic controller. At his command, the pump is turned on / off, as well as the osmotic membrane is flushed and the particles trapped by it are removed into the sewer. Price 54 400 rubles.

Self connection

Before you buy a reverse osmosis system, you need to determine the pressure in the pipeline in your home (an ordinary pressure gauge is enough) and chemical composition water at least in the SES laboratory. This will clarify the parameters of future filters and the need to connect a reverse osmosis system to electric pump. Do not forget to measure the interior space under the kitchen sink if you are going to install the kit here.

When the entire osmosis system does not fit under the sink, you can take out the storage tank separately.

Scheme of work execution:

  1. overlap cold feed into the apartment and drain the water by opening the main kitchen faucet.
  2. Make a tie-in tee by connecting separated pipe sections to the left and right sleeves (use FUM tape to seal threaded connections).
  3. Mount brackets for hanging filters on the cabinet body under the sink.
  4. Connect power to the pump, if necessary.
  5. Install the cassette for replaceable mechanical filters.
  6. Connect the pump downstream of the last pre-filter before the membrane itself.
  7. Here, according to the diagram, a 4-way bypass valve is installed.
  8. The next in this row is the membrane filter, and after it the tank and finishing cartridges are optionally connected. The osmotic is usually fixed with a clamp on drain pipe under the kitchen sink (above the siphon).
  9. Make a tap from the bypass valve to the sewer. If the scheme does not provide for the presence of a drive, the remaining 2 inputs are connected to the drainage at the same time.
  10. The last outlet of the step cleaning is connected to a flexible hose after it is installed on the sink.


Complete with Geyser Prestige, Atoll and Aquaphor filters, there is always a separate spout for drinking water- it remains only to install it above the sink. But you can connect the supply from the tank directly to a special two-circuit faucet or kitchen appliances that require drinking water.

Since a sufficient supply pressure is necessary for the effective operation of a staged water treatment with a membrane, a reverse osmosis installation may require tapping into the pump pipeline if the pressure is weak. Do not forget that such systems become volatile, and you will have to install an outlet under the sink.

System startup and maintenance

A fully assembled structure must be flushed before use. To do this, turn on the supply and close the valve of the drive, passing a few liters of water through the cartridges. The tank itself is washed next with the tap closed. Wait for it to fill, this may take from 40 minutes to 2 hours - depending on the volume of the tank and the pressure in the pipeline. Drain everything again, and the next portion of water will be drinkable.


Stepped preparation systems always contain some water, and if allowed to stagnate, an unpleasant tasting liquid will result. To prevent this from happening, turn on the cleaning daily, releasing at least 500-600 ml for renewal.

The appearance of a musty smell, which the owners sometimes mention in the reviews, is also possible when it stagnates in the storage tank. It needs to be serviced once a month. Some systems, such as Atoll or Geyser Prestige, additionally include a post-filter for final cleaning in the scheme. This is also a way to solve the problem with stagnant water in the cartridges, but you still need to take care of the set under the sink.

REVERSE OSMOSIS. THEORY AND PRACTICE OF APPLICATION.
(

1. WHAT IS "OSMOSIS AND REVERSE OSMOSIS"?

The phenomenon of osmosis underlies the metabolic process of any living organism: nutrients enter each living cell, and metabolites are excreted back. All these processes are carried out through the so-called semi-permeable membranes, which are able to pass the molecules of some substances and prevent the passage of molecules of other substances through them.
The essence of the phenomenon osmosis is that if there are aqueous solutions of salts with different concentrations on opposite sides of a semipermeable membrane that can pass only water molecules, water molecules will move through the membrane from a weakly concentrated solution to a more concentrated one. Moreover, if both solutions are under external, equal pressure (for example, atmospheric), then due to the phenomenon of osmosis, i.e. as a result of the process of water penetration through the membrane, an increase in the liquid level in a more concentrated solution is observed. This difference in the height of the levels of two solutions of different concentrations is proportional to the force under which water passes through the membrane. This power is called osmotic pressure».
If, on the other hand, a solution with a higher concentration begins to be affected by an external pressure that exceeds the osmotic pressure, then water molecules will begin to move through a semipermeable membrane in the opposite direction, that is, from a more concentrated solution to a less concentrated one. This process is called " reverse osmosis". If, however, an external pressure equal to infinity is applied, then, purely theoretically, it is possible to “transfer almost all the water” from a more concentrated solution, and, thus, divide the initial solution into “clean and dirty water”.
From the point of view of technological processes of water purification, reverse osmosis refers to membrane mass transfer processes with a transverse current, in which the source water flow is divided into two streams - "clean" water - permeate and "dirty" water - concentrate. In this case, the ratio of the amount of obtained permeate (purified water) and the amount of initial water, expressed as a percentage ( English recovery of a reverse osmosis), are called: degree of extraction of permeate (purified water) or permeate output (purified water).

2. HISTORY OF THE DISCOVERY AND DEVELOPMENT OF THE PHENOMENON OF OSMOSIS

From what has been said above, it is clear why the origins of the science of membranes are not physicists and chemists, but botanists and physiologists. Man did not invent semi-permeable membranes, he took a ready-made idea from living nature. Indeed, the main studies carried out at the end of the 18th - beginning of the 19th centuries were aimed only at describing and understanding the mechanism of processes occurring in living organisms, and only at the beginning of the 20th century did timid attempts to model the properties of biological membranes from artificial materials begin to appear.
The honor of discovering the phenomenon of osmosis is attributed to the French abbe Jean-Antoine Nolet, who in 1748 first noticed and described this phenomenon. Historians associate a certain incident with this discovery: once the abbe Nole poured the wine he had not drunk into a pig bladder and immersed it in a barrel of water. The next morning, taking the bubble out of the barrel, he noticed that the bubble was swollen. After tasting the wine, the abbot realized that it had become diluted. The abbot concluded that the wine became diluted due to the fact that water penetrated into it through the wall of the bladder under the influence of some force that arose due to the difference in the water content in the barrel and in the wine. At the same time, the abbot noticed that only water penetrated through the wall of the bubble. The abbot called this unidirectional force osmotic pressure, and the process itself - osmosis. (from the Greek ὄσμος, which means push, pressure). Thus, for the first time in the world, Abbé Nolet was able to describe the phenomenon of osmosis and the basic properties of a semipermeable membrane, and osmosis was forgotten. And only a century later another Frenchman - botanist and naturalist Henri Dutrochet a deeper study of this phenomenon was continued, which in turn described the processes of absorption of water and substances dissolved in it by plants by the laws of osmosis.
In the middle of the 19th century, the osmotic permeability of the cell membranes of the century was also studied by the physiologist Mol and the botanist Negeli. And since the end of the XIX century. physical chemists joined them, one of whom was the German scientist Adolf Fick, who in 1855, while studying the transfer through artificial membranes made of nitrocellulose, formulated the phenomenological laws of diffusion, later named after him. Graham first introduced the concept of "osmotic force" in 1854.
Basic Research osmotic permeability of cell membranes, made in 1860-1875 by the Dutch botanist and geneticist Hugo de Vries, one of the scientists who rediscovered Mendel's laws, together with the results of the work of W. Pfeffer (1877), formed an important part of the evidence, on the basis of which Ya.Kh. Van't Hoff built his theory of chemical equilibrium in dilute solutions (1886), and the Swedish scientist Arrhenius built his theory of electrolytic dissociation. In 1888, the German physical chemist Nernst derived an equation for the diffusion potential, and in 1911 Donnan formulated the laws of membrane equilibrium.
On this path of development, biology and membrane research diverge: the study of cellular, biological and membranes of natural origin remains with biology, while chemists and physicists who study membranes shift their interests towards the creation of membranes of various nature and the study of their properties, as well as the description of mass transfer processes Through them. So in the late XIX - early XX centuries. membrane separation methods were discovered: electrodialysis (Maigrot and Sabatier); gas separation (Graham), ultrafiltration (Bechgold). And in the early 1930s, the first mention of the reverse osmosis retention of electrolytes by membranes during the filtration of solutions appeared (Ershler, McBain).
By the end of the 20s of the XX century. significant material on the preparation and use of selectively permeable membranes was accumulated and generalized. The 1930s are characterized by research in this area by Alford, Ferry, Manegold, Grabar, the 1940s and 1950s by the improvement of methods for forming membranes for ultrafiltration and the production of ion-exchange membranes.
In the late 1950s and early 1960s, as a result of the work performed first by Reid and then by Loeb and Suranjan, a design of a spiral OO module based on an anisotropic semipermeable membrane was developed, which is able to withstand enormous pressure and has a high throughput with minimum dimensions. With the participation of Loeb in 1967, a desalination plant with a capacity of 150 m 3 per day was built in the town of Yotvata, which produced clean drinking water from an underground lake with a salinity ten times higher than that of the sea. These scientists showed the technical feasibility of using such membranes for desalination of sea and brackish waters, as well as the separation of liquid mixtures, which gave impetus to further study of membrane separation processes and the production of membranes with desired properties. We will discuss this further in the section on OO membranes.

3. Models for the transfer of water and salts through an OO membrane

Although reverse osmosis technology has become a fairly common method of water treatment, the mechanism for transporting salt and water through the membrane remains a constant subject of debate. At one time, several models were proposed for the transport of water and salts through the OO membrane, general provisions which will be briefly discussed below.
The simplest and easiest to understand model of an OO process is the “sieve” model, or molecular sieve separation model. This model assumes that salt and water are separated on the membrane due to the difference in physical size between the water and salt molecules and the pore size of the membrane. Most of the inhabitants prefer this particular concept of reverse osmosis water purification mechanism. However, it should be noted that in systems where the salt is mainly sodium chloride (common salt), the sizes of the salt molecules (i.e. sodium ion and chloride ion) and water are almost the same. Therefore, this fact makes it possible to exclude the model of the "sieve" mechanism of water separation.
Another model of the transfer mechanism is diffusion transport model(still shared by some researchers), according to which both water and solutes penetrate the membrane by diffusion. According to this concept, water is fixed on the membrane surface due to hydrogen bonds, and this film prevents salts from entering the membrane pores. Water diffuses from one side of the membrane to the other, forming the same barrier layer there. This implies that the rate of diffusion transfer of water is greater than that of dissolved substances.
Finally, the third concept of ion transport through the OO membrane is capillary - filtration model selective permeability. According to this model, a layer of bound water is formed on the surface and inside the pores of a hydrophilic membrane placed in an aqueous solution. Water can bind to the membrane material, for example, by forming hydrogen bonds with the hydroxyl or carboxyl groups of the surface layer of the membrane. Bound water, having a network of directed intermolecular hydrogen bonds, completely fills the pores of reverse osmosis membranes and differs significantly from free water in its properties. For molecules and ions of dissolved substances, this water is a special phase into which they penetrate with a certain distribution coefficient, which can be significantly less than one.
The degree of penetration of ions into the layer of bound water depends on the hydrophilicity of the membrane and the hydrating ability of the ions.

4. REVERSE OSMOSIS MEMBRANES

We have already mentioned that the foundations for obtaining artificial film membranes were laid by Fick in the middle of the 19th century, and at the beginning of the 20th century, Bechgold studied the laws governing the formation of membranes with desired properties. In 1927, the German company Sartorius received the first samples of artificial membranes. After the Second World War, the Americans, using German developments, set up the production of cellulose acetate and nitrocellulose membranes. The effect of electrolyte retention by these membranes during the filtration of solutions through them was first described by Ershler and McBen, and 20 years later was studied in detail by Schmid and Schwartz, which coincided in time with the first studies of reverse osmosis on cellulose acetate membranes (Reid, Breton). At the same time, they were first formulated theoretical basis this phenomenon.
However, the results of these works were of no interest for technology due to the very low productivity of the membranes, which was due to their relatively large thickness (> 100 µm). The reverse osmosis process gained practical significance only after asymmetric membranes were developed. The history of the development of membranes for reverse osmosis is described in detail by Suranjan in the 70s of the last century in his works on reverse osmosis: “ Reverseosmosis" and "Reverse osmosis and synthetic membranes".

4.1 Requirements for RO membranes

So, the reliable operation of a reverse osmosis installation requires reverse osmosis membranes to take into account two main factors - water permeability and salt retention. But, in addition, the OO membrane must have the necessary strength to work at high pressures, chemical resistance and resistance to microbiological contamination.
In contrast to microfiltration and ultrafiltration, impurities retained in the process of reverse osmosis have sizes at the level of molecules, associates, ions, acid residues, which, due to their small size, freely pass through any ultrafiltration membranes. Therefore, for reverse osmosis processes, denser membranes with much greater hydrodynamic resistance are used. Reverse osmosis membranes can be considered as intermediate between open pore membranes (microfiltration and ultrafiltration) and dense non-porous membranes (gas separation).
In contrast to ultrafiltration and microfiltration, the choice of reverse osmosis membrane material directly affects separation efficiency. In other words, the material from which the membrane is made must have a high affinity for the solvent (mainly water) and a low affinity for the dissolved component. The concept of "affinity" refers to the high permeability of the solvent through the membrane and the low permeability of dissolved compounds. That is why the membranes used in reverse osmosis processes are called semipermeable . The foregoing emphasizes that the process of choosing a reverse osmosis membrane material becomes extremely important, since the properties of the solvent material determine the characteristic properties (selectivity) of the membrane. Here, the difference between reverse osmosis membranes and microfiltration or ultrafiltration membranes is clearly manifested, since the cleaning efficiency of the latter is determined mainly by the pore size of the membrane, and the choice of membrane material depends mainly on its resistance to chemicals or resistance to the filtered medium.

4.2 Classification of OO membranes

As such, there is no single universal classification system for OO membranes; therefore, different authors and manufacturers offer different classification systems. Conventionally, OO membranes are divided into:

  • according to its purpose- on membranes for desalination (i.e. retention of electrolytes and surfactants dissolved in water), on membranes for desalination of sea water and on membranes for the separation of organic liquids, etc.;
  • according to its geometric shape- on membranes in the form of films (sheets) and on membranes in the form of hollow fibers;
  • according to the method of obtaining- on membranes obtained:
  • by molding from solutions and melts of polymers;
  • by the formation of polyelectrolyte complexes in solution or on a substrate;
  • by deposition or sputtering of the active matrix on the substrate;
  • by chemical grafting of active groups to an inert matrix;
  • by etching and subsequent washing out of the dissolved components;
  • by deposition on the substrate of products of hydrolysis of salts of polyvalent metals, suspensions of aluminosilicates, solutions of polyelectrolytes, etc.;
  • by membrane morphology or structure- porous and non-porous, symmetrical and asymmetric; with and without a rigid frame, isotropic, anisotropic, composite (composite) and impregnated, etc.;
  • in magnitude and sign of charge- for strongly and weakly charged, cationic (with a negative) and anionic (with a positive fixed charge).

A detailed description of the main types of membranes can be found in our publication on membranes or in specialized literature. Here we will focus only on those characteristics of membranes that, one way or another, affect the process of reverse osmosis.
The amount of flow passing through the reverse osmosis membrane is the same important characteristic, as well as its selectivity with respect to various types of solute. If the choice of material for the membrane is based on the characteristic separating properties of the material-solvent, then the amount of flow passing through the membrane prepared from this material can be increased/decreased by reducing/increasing the thickness of the membrane. In this case, the dependence of the flow rate passing through the membrane on its thickness can be considered as approximately inversely proportional to the membrane thickness.
For this reason, most reverse osmosis membranes are designed as asymmetrical : with a dense top layer (up to 1 µm thick) and a porous underlying substrate (50-150 µm thick). The resistance to transport in such membranes is mainly determined by the dense top layer.
An important class of asymmetric membranes for reverse osmosis obtained by the method of phase inversion are cellulose ethers in particular cellulose diacetate and cellulose triacetate. These materials are extremely suitable for desalination because they are highly permeable to water combined with very low permeability to salts. However, if the characteristic properties of membranes made from these materials are good enough, their stability towards chemicals, temperature and bacteria is very low. In order to avoid hydrolysis of the polymer, such membranes are usually best used in a narrow range of conditions: at pH 5-7 and temperatures below 30°C.
Among other materials that have often been used for reverse osmosis, stand out aromatic polyamides. These materials also have high salt selectivity, but the flow of water through them is slightly lower. Polyamides can be used over a wider pH range of about 5-9. The main disadvantage of polyamides (or polymers with an amide group in general) is their sensitivity to free chlorine (Cl), which causes the destruction of the amide group. At the same time, films made of such materials have a sufficiently large thickness up to 150 μm. Such thick membrane films lead to a sharp decrease in the mass transfer rate. However, this effect is offset by the extremely high membrane surface per unit volume: the specific surface reaches 30,000 m 2 /m 3 .
A third class of useful membrane materials includes polybenzimidazoles, polybenzimidazoles, polyamidohydrazides, and polyimides. However, these materials are very specific and are used in the production of membranes with certain properties. There are two types of membranes with an asymmetric structure:

  • integral or asymmetric membranes
  • composite membranes.

In asymmetric membranes, both the top layer and the substrate are made of the same material. Such membranes are obtained by the phase inversion method. In this regard, it is important that the polymeric material from which the membrane is obtained be soluble in any solvent or mixture of solvents. Since most polymers are soluble in one or more solvents, asymmetric membranes can be made from almost any material. However, this, of course, does not mean that all such membranes will be suitable for reverse osmosis.
In composite membranes, the upper working layer and the substrate located under it consist of different polymeric materials, which makes it possible to optimize each layer separately. The first stage in obtaining a composite membrane is the preparation of a porous substrate. Important characteristics of the substrate are its surface porosity and pore size distribution. Ultrafiltration membranes are often used as a substrate.
Currently, there are two main types of membranes on the market, made from cellulose acetate (a mixture of mono-, di- and triacetate) and from aromatic polyamides. Brief physicochemical characteristics of these membranes are given in Table 4.1 .

Comparative characteristics of OO membranes Table 4.1.

Physico-chemical
characteristics
Aromatic polyamide membranes cellulose acetate membranes
Pressure, MPa
normal working
maximum (reverse permeate)
2,8
0,35
3,0 - 4,2
-
Maximum temperature, °С
  • working
  • storage
35
40
30
30
Permissible pH value 4 - 11 4,5 - 6,5
Hydrolysis susceptibility Not affected Very sensitive
The degree of exposure to bacteria Not affected Very sensitive
Content of free chlorine, mg/l
  • maximum allowable at pH<0,8
  • continuous dose at pH<8
0,1
0,25
0,5 - 1
0,5 - 1
The degree of exposure to other oxidizing agents Very sensitive Medium sensitive
Service life, years 3 - 5 2 - 3
Salt permeability, % 5 - 10 5 - 10

4.3 Basic parameters of reverse osmosis membranes

The main parameters of reverse osmosis membranes are:

  • Membrane specific performance - the amount of purified water passing per unit of time through the unit area of ​​the membrane. In other words, this amount of permeate can produce 1 sq. m. of the membrane surface per day or per hour. Designation: G , J . Units of measurement: m 3 /m 2 *day, m 3 /m 2 *hour (metric system); gallon/square foot*day (GFD), gallon/square foot*hour (GFH) (English-American system).
  • Selectivity defined as the percentage of solute retained by the membrane. In reverse osmosis this is described in terms of NaCl reflection under certain operating conditions (pressure, temperature, pH, concentrate recovery, salinity).
  • Salt permeability - this is the percentage of the amount of salts not retained by the membrane and "penetrated" into the permeate during reverse osmosis, to the amount of salts in the source water.
  • Salt retention - this is the percentage of the amount of dissolved salts retained by the membrane to the amount of salts in the source water. In fact, this is 100% minus salt permeability (%). For a one-component solution, salt retention is equal to selectivity.
  • Degree of permeate recovery (permeate yield) expressed as a percentage and is determined by the ratio of the volume of purified water to the volume of incoming water. Sometimes the value of the degree of selection of the concentrate is used - the ratio of the volume of concentrate to the volume of incoming water.

Let us consider these characteristics sequentially, as well as the factors of the membrane process influencing them.
Membrane specific performance by purified water (permeate flow) J w can be determined from the following expression:

J w = A∙(∆P - ∆p)

(4.1)

Where, ∆P - pressure drop across the membrane; A - coefficient of water permeability (m 3 /m 2 ∙ h ∙ bar) for a given membrane, the value of which depends on the coefficients of solubility and diffusion of water through the membrane; Δπ is the difference in osmotic pressure across the membrane.
Thus, the flow of purified water through the OO membranes J w primarily depends on the difference between the applied pressure and the osmotic pressure across the membrane. In this case, the osmotic pressure directly depends on the total salinity of the source water:

π = R∙T∙c

Where π - osmotic pressure; R - universal gas constant; T - temperature; With - concentration.
It is generally accepted that for every 100 mg/l of solids dissolved in water, there is approximately 0.07 bar (1 psi) of osmotic pressure.
Since the salt content of the permeate is quite low and its pressure is slightly higher than atmospheric pressure, the osmotic pressure from the permeate side is usually neglected.
Specific throughput of the membrane, according to the salt passing through the membrane (dissolved solids) - Membrane Salt Permeability Js is described by the expression:

Js = B∙Δcs

(4.2)

Where, Δcs is the difference in the concentrations of a certain solute on both sides of the membrane ( ∆cs = cf - cp ); IN is the permeability coefficient for a particular solute for a given membrane, the value of which depends on the coefficients of solubility and diffusion of that solute through the membrane.
It is obvious that, first of all, the flow of a certain solute passing through the membrane directly depends on its concentration on each side of the membrane and is practically independent of the pressure difference across the membrane.
Membrane selectivity in relation to this dissolved component, it is defined as the percentage of the dissolved substance retained by the membrane (salt retention), and is described by the expression:

R=/

Obviously, in this expression, only the value of the pressure drop across the membrane is a variable. Thus, it can be argued that the membrane selectivity increases with increasing pressure, which is associated with a decrease in the concentration of a certain dissolved component in the permeate.
Figure 4.1 illustrates the dependence of the membrane specific productivity (a) and salt retention (b) on the applied pressure for a low-pressure polyamide membrane at a temperature of 25 ° C and passing through it an aqueous solution of sodium chloride with a concentration of 5000 mg / l.
As can be seen from graph 4.1a, until the applied pressure exceeds the osmotic pressure of 0.7 MPa (100 psi), no flow of purified water through the membrane is observed, after which the value of the specific productivity of the membrane (permeate flow through the membrane) begins to increase linearly, which is correlated with equation 1.
Salt retention at low pressure is not high, and with its increase it increases rapidly until it reaches an asymptote at a pressure value of 10.5 MPa (150 psi). Most likely, this is due to the fact that at an almost constant value of the specific permeability of the polyamide membrane for sodium chloride, with increasing pressure, there is a rapid increase in the specific permeate productivity. And this leads to dilution of the permeate or to an increase in selectivity.
It should be noted that the dependences shown in Figure 4.1 were obtained when testing the membrane under ideal conditions, i.e. under conditions when there were no edge effects and leaks in the system. In practice, it is always necessary to take into account defects that occur during the manufacture of membranes and the assembly of membrane modules and affect the ingress of raw water into the permeate.
Water permeability coefficient A - the value is not constant and depends not only on the above values, but also on temperature.

The temperature dependence of the membrane module performance can be estimated using the following expression:

Q 25 / Q t = e x

Where Q25 - performance at a temperature of 25 ° C; Q t - performance at temperature T , o C; e is the base of the natural logarithm ( e = 2,71828)

x = U∙

Where U - characteristic constant of the OO membrane (for example, for cellulose acetate is 2723).

Figure 4.2 shows the dependence of the ratio Q25 / Qt on temperature for an OO-membrane made of cellulose acetate.
Typically, the performance of RO membranes at constant pressure increases by approximately 3% per degree of temperature increase. The salt permeability of the membranes also increases in direct proportion to the increase in temperature, but the ratio between the salt and water fluxes penetrating the membrane remains essentially constant at different temperatures. Therefore, it is believed that the selectivity of the membrane is practically independent of temperature.

The selectivity of OO membranes for sodium chloride differs from the selectivity for other inorganic and organic solutes, so manufacturers of RO membranes must provide information on the selectivity of membranes for individual ions or substances.
Table 4.2 shows selectivity data for a typical composite RO membrane.

Table 4.2.

From the table it can be seen that the selectivity of retention of divalent ions such as calcium or sulfate is higher than that of monovalent ions such as sodium and chloride.
All tests described above, and accordingly data provided by RO membrane manufacturers, are carried out at low permeate recovery (low permeate recovery) to minimize the effects of concentration polarization. The parameters under which the OO membranes were tested must be indicated by the manufacturers in the certificate for the OO membrane.
Comparative conditions for testing 4040 series low pressure RO membranes for various RO membrane manufacturers are shown in Table 4.3 (as an example).

Table 4.3.

Test parameter Manufacturer
Hydranautics FILMTEC TORAY Lewabrane
NaCl concentration, mg/l 1500 2000 2000 2000
pH value 6,5 - 7,0 7,0 7,0 7,0
Temperature, o C 25 25 25 25
Degree of extraction of permeate, % 15 15 15 15
Working pressure, MPa (psi) 1,05 (150)* 1,55 (225) 1,55 (225)* 1,55 (225)

* - passport working pressure of the OO-membrane.

5. CONCENTRATION POLARIZATION

We have already said that reverse osmosis refers to membrane mass transfer processes with transverse current. Therefore, as in any hydrodynamic process, the fluid adjacent to the membrane surface moves more slowly than its main flow. While the main flow may be turbulent, the near-surface fluid at the membrane remains laminar. This layer is called boundary layer. When water passes through the membrane (i.e., at the moment of separation of the source water flow into permeate and concentrate), almost all salt ions remain in the boundary layer near the membrane surface. This effect was called concentration polarization and is characterized by the concentration polarization coefficient:

β = C in / C m

Where, Cm - salt concentration in the main stream; From to - concentration of salt in the boundary layer.
Thus, the salt concentration in the boundary layer becomes higher than in the main stream. Due to the resulting concentration gradient, salt ions begin to diffuse back into the main stream.
The effect of concentration polarization, which increases the concentration of salts on the surface of the OO membrane, leads to an increase in the osmotic pressure on it, which reduces the specific permeate productivity of the membrane. This reduction can be estimated using the following equation:

J w = A∙(ΔP - β∙Δπ)

Table 5.1 shows the data on the influence of the effect of concentration polarization on the specific productivity and selectivity of the OO membrane at different salinity of the source water - TDS (2000, 5000 and 35000 mg/l) and initial values: specific productivity 34 l/m 2 ∙ h (20 GFD) and a pressure drop of 2.8 MPa (400 psi) with an initial selectivity (in the absence of the effect of concentration polarization) - 99%, i.e. β = 1.

Table 5.1.

2000 mg/l 5000 mg/l 35000 mg/l
Oud. name, Fw R, %

Oud. name, Fw

R, % Oud. name, Fw R, %
l/m 2 ∙h GFD l/m 2 ∙h GFD l/m 2 ∙h GFD
β = 1.0 34,00 20,0 99,0 34,00 20,0 99,0 34,00 20,0 99,0
β = 1.1 33,83 19,9 98,9 33,66 19,8 98,9 31,11 18,3 98,8
β = 1.5 33,15 19,5 98,5 31,96 18,8 98,4 19,21 11,3 97,3
β = 2.0 32,30 19,0 97,9 29,75 17,5 97,7 4,25 2,5 84,0

The concentration polarization cannot be eliminated completely, but its effect can be minimized by reducing the thickness of the boundary layer. This is achieved by increasing the flow rate over the entire surface of the membrane or by installing various structural elements along the path of the water flow that will turbulize this flow (the so-called turbulators or turbulent inserts).
To overcome the occurrence of the effect of concentration polarization during the operation of systems, it is necessary to always follow the recommendations of the manufacturers of RO-membrane elements for the minimum flow and maximum degree of permeate recovery (permeate yield), especially when it comes to desalination of waters with high salinity or desalination of sea water. Most RO membrane manufacturers provide reverse osmosis design software to minimize the effects of concentration polarization and maximize permeate recovery (permeate recovery).
The decrease in the filtrate flux can be caused by several reasons - concentration polarization, adsorption, formation of a gel layer and clogging of pores. All these factors create additional resistance to transport across the membrane. The contribution of these effects to the total resistance to transport through the membrane is mainly determined by the type of membrane process and the properties of the filtered medium supplied to the membrane. Figure 5.1 schematically shows all types of additional resistances that appear on the membrane.
Ideally, the filtrate flow rate should only be affected by membrane resistance Rm However, if the membrane passes predominantly some of the components, and in some cases completely retains dissolved substances, this leads to the accumulation of molecules that are not able to penetrate the membrane near its surface. Thus, a highly concentrated layer of dissolved substances appears near the membrane, which prevents mass transfer. This resistance is called the concentration polarization resistance. Rcp.
Polarization phenomena are observed in all membrane processes and accompany all separation processes. Over time, the concentration of solutes accumulating at the membrane surface can become very high and cause the formation of a gel layer. This gel-like layer (even very thin) creates a huge additional resistance to the flow of the original liquid ( Rg), sometimes leading to a complete cessation of the separation process. This phenomenon is very typical for high-molecular organic substances (for example, for protein solutions). A feature of the appearance of gel-like deposits on the membrane surface can be considered the process of precipitation on the membrane surface of some poorly soluble salts as a result of their concentration near the membrane surface. Such phenomena are most often encountered during reverse osmosis filtration of brackish water from deep artesian wells (deposits of sparingly soluble salts of calcium, magnesium (for example, carbonates or sulfates)).
In the case of porous membranes, some components may penetrate the membrane and block the pores. This additional resistance is called resistance. blocked pores R p. And, finally, resistance can be caused by adsorption capacity of the membrane material , Ra. Adsorption can occur both on the membrane surface and on the pore walls. As a rule, the contribution of this factor to the total resistance is small (except for the processes of separation of macromolecular substances having an asymmetric structure and an induced dipole moment).
A decrease in the filtration rate adversely affects the technical and economic indicators of both each membrane operation and the operation of the plant as a whole. Therefore, it is necessary to take certain measures to eliminate the causes leading to this phenomenon. This will be discussed below.

6. REVERSE OSMOSIS ELEMENTS

Reverse osmosis elements (RO elements) are formed from reverse osmosis membranes. According to the type of membrane used, OO elements differ in hollow fiber And spiral wound.

6.1.
The first industrial RO elements with an asymmetric membrane based on hollow fibers made of aromatic polyamide with an inner diameter of 42 μm and an outer diameter of 85 μm, on the working surface of which a layer of an asymmetric membrane with a thickness of 0.1–1 μm was applied, were developed by DuPont (France). A standard 10 inch diameter OO element contained about 4.4 million of these fibers. They fit into the module in the form of a tube grid and their ends were sealed with epoxy resin.
Hollow fibers with an asymmetric membrane can be combined into a thick-walled porous cylinder, the strength of which depends on the ratio of the outer and inner diameters. The fibers are arranged in parallel bundles. The gap between the fibers can be fixed with a helical thread wound around the fibers. The solution to be separated moves along the outer surface of the fibers. Under pressure, part of the liquid passes through the walls of the fibers, the permeate moves along the fiber channel. Provided that this ratio remains constant as both diameters increase, the mechanical strength of the cylinder will be constant despite the decrease in wall thickness, which increases the water flow through the wall. This makes it possible to create a membrane with a maximum surface area per unit volume, which at the same time is able to withstand high pressures without mechanical reinforcement. The record specific surface of membranes - 20,000 m 2 /m 3 was achieved by the already mentioned DuPont company in installations with membranes in the form of U-shaped hollow fibers.


In this design (see Fig. 6.1), several hundred thousand fibers, folded in the shape of the letter U (item 4), are mounted inside a fiberglass pressure vessel. For what, cut in size along the length, the hollow fibers are collected in a bundle and bent in half by 180 degrees in the form of "loops" so that the "outputs" and "inputs" of the tubes are on the same side of the bundle. Then the ends of the tubes are filled with a special polymer adhesive. After the glue hardens, a part of it is cut off so that the entrances to the tubes are opened. Then this design is placed in a housing that directs the flow of water, and the filter element is ready!
The high specific surface area of ​​the module has been achieved by using very small fiber diameters (typically hollow fibers have an outer diameter of 45-200 µm and a wall thickness of 10-50 µm). Purified water (see Fig.6.1, pos.1) under pressure is distributed radially inside the module by means of a porous or perforated collector (pos.6) running along the entire length of the module. On the outer surface of the fibers, the source water is separated under pressure into a concentrate (dirty water) and purified water (permeate), which passes through the walls of the fibers (pos. 4) and accumulates in the central channel (fibers), from where it enters the exit from the fibers. Then the permeate is collected by a porous disk (pos.9) and removed from the module (pos.2). The free ends of the fibers are fixed in an impermeable epoxy resin plate (pos.5). The concentrate is collected in the space between the outer surfaces of the fibers, passes through the porous plate (pos. 7) and is discharged through the hole (pos. 3) located in the inlet end plate of the module (pos. 8), in the same place as the source water inlet.
Fig.6.1. Principal design of an OO-element made of hollow fibers.
The numbers indicate: 1 - the input of the source water; 2 - output of purified water (permeate); 3 - concentrate output; 4 - hollow fibers from the OO membrane; 5 - epoxy resin lock; 6 - distribution pipe; 7 - porous disk; 8 - input end plate; 9 - output end plate; 10 - O-shaped gasket; 11 - thrust washer.

In general, the production and improvement of OO elements based on hollow fiber membranes is inextricably linked with DuPont.
In 1974, DuPont developed and introduced the first hollow fiber OO cells in the Permasep series. These were 4-inch cells with a capacity of 5.7 m 3 /day (1500 GPD) and a selectivity of 98.5% (under test conditions: solution - 30000 mg / l NaCl, pressure - 5.5 MPa (800 psi), permeate yield - 30%, temperature - 25°C).
Between 1974 and 1997, DuPont continuously improved the design and performance of its hollow fiber OO cells. So in 1992, two-pass modules (model 6880T) were introduced, having a productivity of 60.5 m 3 / day (16000 GPD) and a selectivity of 99.55% (under test conditions: solution - 35000 mg / l NaCl, pressure - 6.9 MPa (1000 psi), permeate yield - 35%, temperature - 25 ° C).
And just before the hollow fiber OO cell was discontinued, the SW-H-8540 was introduced as a single unit 8 ½" 40" long with 30.3 m3/d (8000 GPD) and 99 selectivity. 6% (under test conditions: solution - 35000 mg / l NaCl, pressure - 6.9 MPa (1000 psi), permeate yield - 35%, temperature - 25 ° C).
For seawater desalination in a single pass, between 1983 and 1997, DuPont developed Permasep SWRO hollow fiber OO elements with the following characteristics:

  • permeate yield 30 - 50%;
  • working pressure 6.9 - 8.3 MPa (1000 - 1200 psi);
  • permeate quality< 500 мг/л при исходной морской воде с солесодержанием с 36000 - 45000 мг/л и температурой 17 - 38 о С;
  • specific electricity consumption 3.7 - 8.2 kW * h / m 3.

Initially (in the 1970s), hollow fiber RO elements had some advantages over spiral type RO elements due to the simplicity of design and higher operating pressure (up to 8.3 MPa (1200 psi)), which made it possible to achieve a higher output permeate (up to 60% at an initial salt content of 38,000 mg/l and a temperature of 25°C).
However, a number of intractable shortcomings in the operation of hollow fiber membranes became the starting point, which made it possible to gradually oust OO elements based on them from the market. So, for example, it was found that in order to obtain a certain specific productivity, it is necessary to apply a pressure of 50% less to a spiral wound module than to a hollow fiber one.
The high specific surface area of ​​the membranes is ultimately due to the small transverse dimensions of the channels through which the concentrate and especially the permeate move. This leads to a large loss of pressure in these channels. Therefore, the flow velocity along these channels is limited. As a result, in devices with hollow fibers, the difficulties associated with concentration polarization are strongly pronounced, which forces pretreatment to be especially careful, for example, the SDI index should be less than 3 (up to 5 is allowed for spiral wound modules).
In addition, sediments on the membranes during their fouling and fouling with hardness salts were difficult to remove due to low cross-flow rates and a relatively limited operating range of pH values ​​(4 - 11).
And in the late 80s and early 90s of the last century, DuPont hollow fiber OO elements began to lose their positions in the market, giving way to spiral wound ones, the production technology of which began to develop rapidly due to fierce competition from such companies as: Filmtec / Dow , Rohm & Haas / Hydranautics, Toray, Fluid Systems / Koch, TriSep and Osmonics / General Electrics, etc. All this led to a decrease in prices for spiral wound modules, and for DuPont the production of hollow fiber OO elements becomes unattractive from an economic point of view vision. DuPont is curtailing their production.
However, the production of hollow fiber OO elements in the world has not completely disappeared. Several firms continue to produce such modules.

6.2. Spiral wound reverse osmosis elements.
Spiral wound reverse osmosis elements(another name roll reverse osmosis elements) have been widely used.
In this design ( see Fig.6.2 ) on the central pipe (pos.7), through which the filtrate is discharged, a “sandwich” is wound, consisting of two OO membranes (pos.4), turbulator meshes (pos.5) and a gasket for collecting permeate (pos.6) . The key stage in the manufacture of spiral rolled membrane modules is the layer-by-layer laying of membranes and gaskets around the perforated permeate outlet tube, rolling and sealing this spiral structure. The compressive load that occurs during rolling causes the helix to compact and, as a result, the raw water pad and its adjacent layers to compress. After rolling, an outer coating of reinforced glass fiber (pos. 8) is applied to the resulting cylinder and antitelescopic covers (pos. 9) are installed.
The water to be demineralized (pos. 1) flows parallel to the central pipe through the gap formed by the turbulator mesh (pos. 5) between the two active surfaces of the membranes (pos. 4) and is forced through the membranes. The filtrate (permeate) is collected inside the porous material (pos.6) and moves along it to the central pipe (pos.7). The concentrate (pos.2) is discharged through the perforation in the lid (pos.9).
Of course, the reverse osmosis membrane is the central technological element of the entire design, however, one cannot ignore other structural elements that can improve the mass transfer process and increase the energy efficiency of the reverse osmosis process.

Figure 6.2: Principal design of a spiral wound OO element.
The numbers indicate :
1 - source water;
2 - concentrate output;
3 - output of the filtrate (permeate);
4 - OO membrane;
5 - gasket (grid-turbulator);
6 - gasket for collecting permeate;
7 - perforated pipe for collecting permeate;
8 - outer coating of fiberglass;
9 - cover.

Despite its cylindrical configuration, the roll-type RO element is essentially a cross-flow mass transfer device, as the source water passes through the module in the axial direction, and the permeate moves in a spiral in the radial direction towards the perforated tube to collect it.
Over the past 20 years, the design and performance of spiral wound membrane elements have been greatly improved. Their productivity has more than doubled, and salt permeability has been reduced by almost three times. So, for example, FILMTEC managed to increase the membrane surface area in an 8-inch module from 28 m 2 (300 sq. ft) (1980) to 41 m 2 (440 sq. ft), and most importantly, that the paths for further increases in surface area are also visible. This can be achieved by reducing the thickness of the spacers, although it will be possible as long as the module structure remains rigid. But the appearance on the market of a new series - 16-inch membrane OO-elements dramatically increases the surface area by 4.3 times to 158 m 2 (1725 sq. ft).
In addition, the maximum working pressure of the spiral-wound RO membrane elements increased from 6.9 MPa (1000 psi) to 8.3 MPa (1200 psi), which increased the degree of permeate removal to 60% or more. This was made possible by making structural changes to the permeate and concentrate removal systems. Work continues to improve the design of connecting elements, including the end caps of the OO element.
Recent advances in the design of the spiral wound RO element are contributing to significant cost savings in the manufacture of reverse osmosis plants and making this technology more accessible and widespread in various parts of the world.
For some time now, all manufacturers of rolled membrane elements have come to a unified system of design dimensions that allow, if necessary, to replace an OO element manufactured by one company with another, similar in size and characteristics. In accordance with this system, RO elements for industrial and semi-industrial applications are produced with outer diameters of 2.5”; 4"; 8" and 16". The length of the modules varies.
Figure 6.3 and Table 6.1 show sketches and dimensions of reverse osmosis roll elements with outer diameters of 2.5” and 4”.

Table 6.1.

OO module type Outer diameter (D), mm (in) Length (A), mm (in) Connection dimensions
Length (B), mm Diameter (C),
mm
2514 61 (2,5) 356 (14) 30 19
2521 533 (21)
2526 660 (26)
2540 (61-1016) * 1016 (40)
4014 99,4 (4,0) 256 (14) 27
4021 533 (21)
4025 635 (25)
4040 (100-1016)* 1016 (40)





Figure 6.4 and Table 6.2 show sketches and dimensions of reverse osmosis roll elements with outer diameters of 8” and 16”.

Table 6.2.

* designations of domestic elements

In the following discussion, we will focus on the 8" helically wound RO element configuration, which is most commonly used in RO installations for industrial and municipal water supplies.

7. REVERSE OSMOSIS MODULES
OO elements are assembled into packages inside special holders (reverse osmosis modules) that provide both sealing of the ends of the OO elements and their “work”. Holders of OO elements, or whatever they are called high-pressure housings of reverse osmosis membranes, available for all sizes of 2.5” OO elements; 4"; 8” and 16” with different lengths and depending on the number of membranes placed in the housing, they can be single-cartridge and multi-cartridge (similar to filter holders for microfiltration). The material for the manufacture is reinforced fiberglass or stainless steel.

During operation, the pressure of the treated water is perceived only by the body itself. Structurally, the holder for OO elements is a hollow cylinder with a number of sealing elements and end caps. Inlet/outlet nozzles for water inlet/outlet are placed either on the body shell or on the end plates. The figure shows a sectional view of the end face of a high-pressure composite housing for 4” diaphragms with and without an OO element installed.
IN The holder body can be sequentially placed from 1 to 8 OO-elements in such a way that the concentrate from each previous element is the source water for the next one.

Basic design of a typical OO module high pressure made of composite materials, in which three spirally wound OO elements are placed, is shown in Figure 7.1. Source water (pos.1) enters the OO-module through a threaded hole located on the end inlet cover (pos.8), is distributed inside the housing of the OO-elements holder (pos.4) and is fed to the first OO-element (pos.5 ). To center the OO-element, a sleeve is inserted into the central drainage channel of the OO-element, which simultaneously serves as a plug for the permeate flow. In the OO-element, the source water is separated into permeate and concentrate. The first is collected in the central drainage channel (perforated pipe), and the second is sent to the next OO element. It also has a similar division. At the same time, the U-shaped gasket of the second OO element separates the flow of source water (concentrate of the first OO element) from the concentrate flow forming on the second OO element. Further, in the third. All OO-elements are interconnected along the central drainage pipe by bushings, which are equipped with O-shaped sealing rings recessed into the groove to prevent displacement during installation. The channel formed in this way collects all the permeate that was obtained from all the OO elements. Permeate is discharged from the last OO-element in the row in the same way through the sleeve, which is connected to the end cap (pos. 2). The concentrate from the last OO element is also discharged through the threaded hole in the end cap (pos.3).



Figure 6.2: Principal design of a spiral wound OO module with three OO elements.
The numbers indicate :1 - source water; 2 - output of the filtrate (permeate); 3 - concentrate output; 4 - housing of the OO module; 5 - spiral wound OO elements; 6-U-shaped gasket of the OO-element; 7 - bushing connecting the OO-elements for collecting permeate;
8 - inlet end cap; 9 - outlet end cap.

8. REVERSE OSMOSIS UNITS

Reverse osmosis has a very wide range of uses, which can be conditionally divided into two main groups:

  1. Solvent cleaning . In this case, the product is permeate.
  2. Solute concentration . In this case, the product is a concentrate.

The main use of reverse osmosis is water purification, mainly the desalination of brackish water and especially sea water in order to obtain drinking water. Another important field of application of reverse osmosis plants is the use of reverse osmosis as a stage of preliminary desalination of water in the production of ultrapure water (deionized water) for the semiconductor, medical and thermal industries.
At the stage of concentration, reverse osmosis is widely used in the food industry (concentration of fruit juices, sugar, coffee) and in the dairy industry (for the concentration of milk at the initial stage of cheese making), as well as in wastewater treatment (in electroplating for the concentration of galvanic waste).

8.1. The composition of the reverse osmosis plant.
Now, let's focus on the purpose of the individual components of the reverse osmosis installation. On Fig.8.1 a general view of the OO-installation is given. On Fig.8.2 a schematic flow diagram of a typical single-stage reverse osmosis plant is presented.
The first stage of the reverse osmosis process is the fine purification of the source water from mechanical impurities. Usually for For this, cartridge-type filters are used, placed in single-cartridge or multi-cartridge filter holders, depending on the performance of the OO unit. The mechanism of operation of cartridge filter elements refers to microfiltration, namely to deep and / or surface filtration, i.e. mechanical impurities retained by the filter element accumulate inside the layer of the filter partition.
Water purified on cartridge filters is supplied to a high-pressure pump, the purpose of which is to achieve the pressure of the initial medium of the calculated pressure for the implementation of mass transfer processes occurring on semi-permeable reverse osmosis membranes. The selection of a high-pressure pump is based on its operating characteristics. In this case, the operating point of the pump should be in the range from 0.6 - 0.7 of its maximum performance.
If it is impossible to establish “parity” between the pressure and the pump capacity (and this happens most often), a bypass valve is installed between the suction and discharge pipes of the pump, with the help of which this operation is carried out (according to the readings of the rotameter and pressure gauge of the source water entering the reverse osmosis modules). Adjustment of the process of increasing the pressure of the source water is made once in the process of commissioning. During the operation of the RO-installation, only the control of the operating parameters of the source water is carried out.
From the high-pressure pump it enters the OO-modules, in which reverse osmosis elements , on the OO membranes of which the separation of the source water into permeate and concentrate actually occurs. The concentrate leaving the reverse osmosis unit has a sufficiently high pressure and its transportation to the place of discharge or disposal does not cause any particular difficulties. The permeate pressure after a reverse osmosis plant rarely exceeds 1 atm. Therefore, most often it has to be fed into a storage tank, from where it is transported to further purification stages using a booster pump.
Several separate OO modules, placed in parallel or in series with respect to each other, form a cas-cad. The task of an engineer designing an OO installation is to assemble the modules in such a way as to optimize the system at the lowest cost of the product. The flow pattern in the module is one of the main factors determining the degree of separation achieved and the quality characteristics of the installation. In principle, there are two basic flow configurations used in single-stage or multi-stage reverse osmosis processes: 1) single pass system and 2) recirculation system (seerice. 8.3 - schemes of single-pass and recirculation systems).

single pass circuit recirculation circuit

In a single-pass system, the raw solution passes through a single module (single-stage system) or a system of modules (multi-stage system) only once, i.e. there is no recirculation here. In other words, the volumetric flow rate over the membrane decreases as you move from the entrance to the module to the exit from it. In multi-stage single-pass processes, this reduction in flow is compensated by a certain assembly of modules, the so-called conical cascade scheme (“herringbone”), as shown in rice. 8.4 a . With this configuration, the plant can be designed so that the flow rate remains virtually constant. This system is characterized by the fact that the overall length of the path over the membrane and the pressure drop are large. Volume reduction factor, i.e. the ratio of the initial volume of raw material and the volume of concentrate, is determined mainly by the herringbone configuration, and not by the applied pressure.
Another configuration is the recirculation system shown in fig.8.4 b . In this case, the raw material is compressed and pumped several times through the same stage, consisting of several modules. Each stage is equipped with a recirculation pump to optimize hydrodynamic conditions. There is only a small pressure drop in each stage where the flow rate and pressure can be adjusted. The feed recycle system is much more flexible than single pass systems and is preferred in microfiltration and ultrafiltration processes where strong concentration polarization and rapid membrane deposition can be expected. At the same time, for simpler tasks, for example, in the desalination of sea water, the use of a single-pass system is economically justified.



All reverse osmosis units are equipped with an automatic control and monitoring system, which, as a rule, includes: a controller for controlling an OO unit, a conductometer, flow meters (rotameters), pressure gauges and pressure sensors.

9. OPERATION OF REVERSE OSMOSIS INSTALLATIONS

At the beginning of this section, the following two factors that exist in the operation of an OO installation should be noted:

  • There is not a single OO installation that would work stably without the proper performance of all regulated work.
  • Proper operation of the installation cannot always prevent the formation of stagnant water zones.

Let's understand the term proper or correct operation". During the operation of the OO-installation, this concept includes not only the careful execution of operations to maintain the technological parameters of the operation of the reverse osmosis unit, but also the systems for the preliminary preparation of initial solutions, and the replacement of filter elements, etc., etc.
A water treatment plant using reverse osmosis technology, as a rule, includes separate sections, which are shown in Figure 9.1.


The first section, based on the experience of engineering practice, is equipped with equipment for pre-treatment of water, which is designed to prepare water to the requirements corresponding to the parameters recommended by manufacturers of reverse osmosis elements. After pre-treatment, water is supplied to the reverse osmosis unit, to reverse osmosis membrane elements placed in high-pressure housings. Under the influence of pressure on the surface of the membrane, the source water flow is divided into a product (permeate), which passes through the membrane, and into a given amount of waste (concentrate), which is discharged into the drain. The reverse osmosis permeate is sent to a further processing section (permeate post-treatment section), where equipment is placed to remove carbon dioxide from the permeate (decarbonization equipment) and / or the chemical composition of the permeate is adjusted (chemicals are dosed) to the required conditions of the main technological process.

9.1. Pre-treatment of water.
Choosing the right solution preparation method is the first step to reducing membrane fouling. Often, a lot of time and effort is spent cleaning the membranes, while the pre-treatment step of the stock solution is simply forgotten.
What does the term "correctly treated water" mean? We would like to draw your attention to the indicators of the content of individual ingredients in the source water, the values ​​of which determine the operational characteristics of the installations and the reliability of their operation. The values ​​of the content of these substances are indicated in Table 9.1 . For comparison, the same table shows the values ​​of the same substances according to the requirements of SanPiN 2.1.4.1074.

Comparative indicators of water quality Table 9.1.

Ingredient name Units Requirements in accordance with SanPiN Source water requirements for RO installations
Suspended solids (turbidity), no more mg/l 1,5 0,6
Total hardness, no more mg-eq/l 7,0 20
Total salt content, no more mg/l 1000 50 000
Color, no more degree 20 3
pH value of source water, no more 6 - 9 3 - 10
Colloidal index (SDI), no more mg/l - 0,4
Iron total, no more mg/l 0,3 0,1
Oil products mg/l 0,1 absence
Hydrogen sulfide and sulfides mg/l 0,003 absence
Hard abrasive particles mg/l - absence
Free active chlorine no more mg/l 0,3 0,1
Permanganate oxidizability, no more mgO 2 /l 5,0 2,0

Differences in the requirements for source water according to SanPiN and for OO plants relate not only to organoleptic indicators of water quality, i.e. suspended solids and water color, but also oil products, surfactant , oxidizability, colloids (iron, silicic acid). Therefore, much attention should be paid to the processes of preliminary preparation of source water before supplying water to the reverse osmosis unit.
Particular attention should be paid to the active chlorine content. The fact is that active chlorine has a very negative effect on reverse osmosis membranes and causes their destruction (destruction). Therefore, if chlorine-containing agents are used in the process of pre-treatment of water, it is necessary to introduce the stage adsorption water purification on active carbon . The same process will help to reduce such an indicator as the oxidizability of water, which is responsible for the total content of organic compounds in the source water.
Depending on the degree of contamination of the source water, the methods of its treatment include: heat treatment, pH control, proportional dosing of complexing agents, biocides, coagulants using dosing pumps, aeration, iron removal, adsorption on activated carbon, mechanical purification and clarification of water, softening (Na -cationization), preliminary microfiltration or ultrafiltration, water disinfection using.
The dosing of chemicals in the process of preliminary water treatment is becoming an integral process for OO systems. Supply tanks for chemicals such as antiscalant, coagulant or chlorine or reducing agents (eg sodium metabisulphite) can themselves become sources of contamination. To prevent this, carefully review any recommendations from the RO system supplier or chemical manufacturer to determine the appropriate conditions for selecting tank operating conditions. Often the best approaches to solving this problem are: use of regular suppliers, complete replacement of reagent stocks and complete cleaning of tanks.

9.2. Operation of OO installations
There are no special problems in the operation of reverse osmosis plants with properly prepared water.
As we have already seen, the degree of saturation of the permeate with the ingredients present in the source water depends on the type of reverse osmosis membrane element used, as well as on the material of the membrane itself. Usually, after sufficiently properly prepared water, the degree of water desalination in a reverse osmosis plant is 95 - 98%, that is, the electrical conductivity of the permeate is in the range from 20 to 50 mS, or in terms of water resistivity 20 - 50 kOhm cm.
During the operation of the RO-unit, the following should be controlled: water pressure before and after prefiltration (before the RO-unit), pressure developed by the high-pressure pump (at the inlet to the RO-modules), concentrate pressure, concentrate, permeate and feed water flow, feed water temperature , specific electrical conductivity of the permeate and periodically the source water.
The preferred mode of operation of the OO plant is continuous. If the OO system cannot operate continuously, it must be programmed to automatically turn on for 15 minutes every 4 hours of inactivity to circulate flows in the system. This will help prevent the formation of deposits (primarily biofilms).
Table 9.2 provides some examples of common problems that may arise when operating an OO installation.

Table 9.2

Problem Cause Troubleshooting options
Increased salt content of permeate 1. Deterioration of water quality 1. Reduce the proportion of permeate (increase in concentrate at a constant flow of source water)
2. Decrease in concentrate consumption at a constant consumption of source water 2. Increase the concentrate consumption at a constant consumption of source water
3. Low pressure of source water. 3. Increase the pressure of the source water
4. The membranes are dirty 4. Carry out chemical cleaning of membranes
5. Broken pump 5. Replace the pump
6. Damaged membranes 6. Replace membranes
7. Conductivity sensor dirty 7. Clean and calibrate the sensor
Reduced permeate consumption 1. Decrease in temperature 1. Increase temperature and/or pressure
2. The membranes are dirty 2. Carry out chemical cleaning of membranes
3. Damaged membranes 3. Replace membranes
4. Low pressure source water 4.See Further
Low feed water pressure 1. Clogged pre-filters 1. Rinse or replace filter cartridges
2. Low pressure source water 2. Increase the pressure
3. Damaged solenoid valve at the inlet to the unit 3. Replace solenoid valve

With proper operation of RO systems, one cannot ignore such operations as standard chemical cleaning and disinfection of RO elements (surfaces of OO membranes). The following criteria should serve as a key to determining cleaning and disinfection cycles: plant pressure drop, capacity, flow rates, temperature, and microbiological contamination level. There are two general rules for determining when flushing and disinfecting an OO system is necessary:

  • the first, when the performance of the OO installation decreases by 10 - 15%,
  • the second, when there is a tendency to reduce the flow rate and increase the pressure drop.

With proper feed water pre-treatment, the membrane should last at least 3 years. However, performance and quality can degrade over time due to deposits or biological contamination (more on this in Section 10). Periodic chemical flushing is necessary to maintain the membrane in working condition. The composition of the washing solution depends on the nature of the contamination, here are a few examples:

  • In the event of a decrease in the quality of the permeate - a solution of 2% citric acid or 0.1% hydrochloric acid prepared on the permeate (pH ~ 3, t< 30 о С).
  • In the event of a decrease in the productivity of the installation at a constant initial pressure, temperature, etc. - with a solution of 0.1% sodium dodecyl sulfate or Trilon B + 0.1% NaOH (pH< 10, t < 30 о С).

The reverse osmosis plant is flushed with a chemical wash unit, which is either part of the RO plant or can be a separate unit. All solutions for chemical washing are prepared on the permeate produced by the RO plant.

9.3. Water treatment after reverse osmosis installation.
We have already said that the pressure of the permeate after a reverse osmosis plant rarely exceeds 1 atm (0.1 MPa). Therefore, most often it is fed into the storage tank, from where it is transported with the help of a booster pump to further purification stages, where it is brought to the composition required by the conditions of the main technological process. For example, such stages can be:

  • Decarbonization (removal of carbon dioxide from the permeate).
  • Additional microfiltration cleaning on cascade cartridge filters.
  • Disinfection of water using ultraviolet sterilization units.
  • Correction of pH value and chemical composition by proportional dosing of various chemicals, also by means of bulk filters with corrective backfill.
  • Adsorption treatment, either to improve organoleptic properties or to produce water with a low total organic carbon content.
  • Deep desalination of water (OO-permeate) using ion exchange units (H-cationization, OH-anionation, mixed-bed filters) or using electrodeionization units.

The technological scheme of permeate post-treatment is selected based on its composition and requirements for purified water.

10. CONTAMINATION OF REVERSE OSMOSIS ELEMENTS AND MEMBRANES

10.1. General information.
What can be deposited on the membranes?
In order to understand this, we will use some concepts of the theory of hydration.

From theory It is known that after the dissolution of substances in water around their particles: ions, molecules, small associates, micelles (large associates), hydrate shells are formed. Those. all particles (with rare exceptions), being charged, tend to attract and orient the dipole water molecules around them, i.e. distort or even destroy the original structure of water. The degree of manifestation of this trend depends on the size of the charge and the configuration of the particle (see figure). In this case, a two-layer hydration shell appears around the ions, polar molecules, and micelles, which consists of a dense layer of oriented water molecules ( layer A ) and loose layer ( layer B ) from semi-oriented water molecules.
Dense layer of hydration shell ( layer A ), can be considered as consisting of water clusters linked by hydrogen bonds, the structure of which is specific depending on the nature of the hydrated particle. This layer is sufficiently strong, strictly ordered under the action of an electric field, and the water molecules in this layer are, as it were, “frozen”. During electrolysis, it moves along with the ion. The layer thickness is determined by the charge density of the ion (particle), i.e. the ratio of the charge of an ion (particle) to its (its) diameter. Some time later layer A began to be called primary hydration layer or primary hydration shell .
Secondary hydration shell (layer B ) is much less firmly bound to the ion, this is a kind of "melting" zone, intermediate between zone A And zone C , where the tetrahedral structure of pure water is preserved. Those. from zone B V zone C water molecules can move and vice versa.
The average lifetime of water molecules in a hydration shell depends on the nature of the particle, the concentration of dissolved substances, and temperature.
In 1951, after the coordination numbers for various electrolytes were established, it became possible to calculate the concentrations of electrolytes at which all the water present in the solution is included in the composition of the first hydration shells. Structurally, such a solution can be schematically represented as a system composed of only one layer of hydrated ions in contact with each other with their hydration shells ( zones A ). The boundary condition for the emergence of such a system (i.e., the concentration of the electrolyte in the solution) was called limit of complete hydration of an aqueous solution (GPG). For different electrolytes, this concentration is in the range from 2.14 to 4.63 mol/l.
When the solution is diluted, water molecules begin to build a secondary hydration shell ( zone B ). The concentration of the solution at which all the available water enters the primary and secondary hydration shells was called limit of long-range hydration of an aqueous solution (GDG ).
Consider what happens when the solution is concentrated (see figure). In a dilute solution, there are both GDG (layer A + layer B ) and layer C with the tetrahedral structure of pure water ( state I ). As the solution is concentrated (electrolyte is added to the solution), free water is first exhausted from layer C (state II ), and then a layer of secondary hydration ( layer B ) up to the formation PIP (state III ).
The reverse osmosis process is always associated with the concentration of solutions, so let's consider how the main characteristics of the membrane change - specific productivity ( G ) and holding capacity ( R ) with increasing concentration ( C1 ).
As the concentration increases in the "water - solute - membrane" system, the following changes occur:
1 - all free water first passes into secondary hydration shells ( GDG ), and then to primary ( PIP ). The size of the hydrated ion decreases;
2 - the osmotic pressure of the solution increases proportionally C1 , which reduces the mass transfer driving force at constant operating pressure;
3 - the thickness of the bound water layer decreases due to competition for water between ions and polar groups of the membrane material in favor of ions.
Such a qualitative description leads to the assumption that both the specific productivity and the retention capacity should decrease as the concentration increases, which is observed in the experiment (see figure).



From these graphs, one can clearly see the dependence that the decrease G And R begins when the solution "exhausts free water" (the value is reached GDG ), and to zero G And R come in a zone close to the value PIP .
Since one component passes through the membrane, and the second is delayed by it, a change in the concentration ratio in the volume of the initial solution necessarily occurs. After all, this is the goal of the membrane separation process, but these changes are very unevenly distributed in the volume of the solution. Therefore, there are so-called polarization phenomena on the membrane , i.e. events occurring in a thin layer of the mixture being separated near the membrane surface due to its semi-permeability.
Let us consider a typical picture of such a distribution over a component that is retained by the membrane.
The flow of the initial solution moves along the membrane with a volume flow W and with the concentration of the delayed component So . Under the action of a driving force (pressure gradient), a permeate flow penetrates the membrane G with component concentration Wed< Со . Due to the fact that the outflow of water occurs from the solution layer adjacent to the membrane, the concentration of the component in this layer increases as it approaches the membrane surface.
The figure shows a stationary process at w = const , G = const .
The thickness of the layer in which growth becomes noticeableWITH , is δ , and the maximum concentration on the membrane surface isCm . Thanks toCm> Co , there is a diffusion transfer of the component from the membrane to the core of the flowD*dc/dx .

This nature of the change in concentration will be the same for any component retained by the membrane - inorganic ions and salts, water-soluble organic compounds, including high molecular weight ones, for colloidal and suspended particles.
It is clear that all baromembrane processes are accompanied by polarization phenomena. The differences will be that different substances behave differently during concentration: some may exceed the solubility limit and they will precipitate, some form spatial networks and turn into a gel, some begin to accumulate on the membrane due to adsorption and surface forces. The figure conventionally shows these situations in the form of additional resistance to mass transfer through the membrane.


Rp - pore overlap; Ra - adsorption; Rm - membrane;
Rg - gel layer; Rcp - layer of high concentration of dissolved substances.

In general, the intensity of formation and retention strength of deposits on the membrane depends on the porosity of the membrane, the charge and degree of hydrophilicity of its surface, the concentration of particles and impurities in the source water, their nature and size, temperature and pH value, the presence of conditions for adsorption, chemical interaction, crystal formation and the possibility of polymerization of substances on the membrane surface, as well as other factors. There is no general theory of the processes of formation of deposits on membranes, therefore, in engineering practice, experimental and operational methods of evaluation are most often used.
All deposits formed in the reverse osmosis module, as a rule, are divided into three large groups, which are distinguished both by their composition, structure and particle size of the sediment, and by the mechanism of deposit formation:

  1. Precipitation of suspended, colloidal particles and microorganisms.
  2. Precipitation of sparingly soluble compounds.
  3. Deposits of high-molecular organic substances.

Let's take a look at these three groups one by one.

10.2. Precipitation of suspended and colloidal particles.
So to first group include precipitation of suspended and colloidal particles, as well as microorganisms. Those. The bulk of the sediments of this group consists of microparticles of organic and inorganic origin, coming both from the source water and formed during the preliminary treatment of the source water before reverse osmosis when it interacts with technological filter media, structural elements of the installation and with the atmosphere.
First of all, these are heterogeneous particles of various dispersity: colloidal and suspended inorganic and organic substances (various dust, metal oxides and hydroxides, sand - undissolved SiO 2 , clay and alumina, associates of organic substances and high molecular weight organic compounds (HMC), etc. ), as well as microorganisms that form a biofilm on the membrane surface.
Present in source water suspended microparticles with sizes from 1 to 25 microns, can block (clog) channels between membrane packages, and at a high speed of movement along the membrane surface, they can have a kind of abrasive effect on it, i.e. can mechanically damage the barrier layer of the membrane. All this, as a rule, leads to irreversible damage to the membrane element.
In some cases, contamination of the pressure channel of the reverse osmosis element can lead to the failure of the device. So, for example, if the gasket-turbulizer-separator of the spiral membrane element is contaminated, the pressure drop from its different ends can increase until the element is destroyed due to the telescopic shift of the layers of the roll (spiral) relative to each other (the so-called " telescoping», from English telescoping). In this case, there will be a “leakage” of the source water into the permeate, which will be seen from a sharp sudden increase in the productivity of the installation and an increase in the salinity of the permeate.
Smaller microparticles and colloids, together with other deposits, which, as a rule, belong to the second group (which will be discussed below), and microorganisms form a deposit on the membrane surface that prevents its normal operation.
In practice, the amount of suspended particles in water is most often associated with the turbidity index, the analytical control of which is carried out by optical and photometric methods (GOST 3351). However, with regard to the resolution of these measurement methods, i.e. sizes of microparticles present in the analyzed water, then when using photometers (turbidimetric or nephelometric methods of measurement) it can be stated with confidence that their real resolution is 1-1.5 microns, and when visually determining turbidity (by the degree of turbidity of a column 10- 12 cm in a turbidity test tube) - more than 2-3 microns.
Thus, when measuring the turbidity index, particles smaller than 1 µm, including colloids, are not registered by these methods. It should be noted here that, according to the results of many years of research in the operation of baromembrane apparatus, microparticles with sizes less than 0.45 microns are considered the most dangerous. Microparticles with such sizes can be "counted" using a laser microparticle counter, the operating principle of which is based on the method of determining the size of microparticles by the intensity of small-angle light scattering. Devices of this class are able not only to recognize the size of microparticles, but also to determine their number in a certain range. True, this method of measuring the amount of microparticles can only be laboratory, in addition to the fact that it is rather laborious and expensive.
In order to simplify the procedure for determining the amount of microparticles supplied to membrane plants with source water, at one time ASTM standards introduced colloidal index or sediment density index - SDI (short for English Silt Density Index), which served as a characteristic of the degree of water contamination with mechanical and colloidal impurities and its suitability for supply to membrane plants. Currently per ASTM D-4189 SDI - index is a mandatory primary test of the quality of the source water, in the most general form showing the probability of the formation of sediments of colloidal and suspended substances that can contaminate the surface of the membrane elements.
The measurement of the SDI colloidal index is a rapid test that is performed daily (or as needed, for example, weekly - after a set of static data indicating the stability of the SDI colloidal index of the source water). Water sampling is carried out, as a rule, after cartridge filters before water is supplied to the membrane unit. The test can also be used to control the performance of clarifiers, pressure mechanical filters, both bulk and cartridge (mesh, depth, surface, etc.), iron removal filters, etc. The SDI method cannot be used to assess the service life of membrane elements, because there are no clear correlations between the composition of the source water and the value of the SDI index.
Silt Density Index (SDI-index) is an index of the density of suspended particles per unit volume of water - it determines the decrease in membrane performance due to the formation of contaminants on their surface, consisting of suspended and colloidal microparticles. The method for its determination is based on measuring the filtration time of a given volume of source water (usually 500 ml) through a calibrated microfiltration membrane with a pore size of 0.45 µm at a constant pressure drop across the filter of 0.207 MPa (30 psi) and a constant temperature. The choice of the pore size of the membrane - 0.45 μm is justified by the fact that the value of the equivalent diameter of microparticles of 0.45 μm is a transition from a dissolved state to a suspended one.
By values SDI 15 one can judge the complexity of the required pretreatment of water for membrane processes:
SDI< 5 Предварительная подготовка не требуется
SDI 5 - 10 One step pretreatment required
SDI > 10 Requires two-step preconditioning

SDI values ​​for typical natural water sources:

Source water type Maximum SDI Minimum SDI
Artesian 5 2
superficial 175*) 5

*) - for some open reservoirs, the value of the SDI index can reach 500.

By the value of the permissible critical value of the SDI index, one can judge the class of membrane elements (for leading manufacturers, the value of the SDI index of the source water ( SDI 15 ) is allowed: for artesian water- up to 5; For surface water- before 18).
To reduce the SDI value, preliminary treatment of the source water is used. As a rule, well-known methods such as filtration and coagulation are used to remove suspended solids and colloids.

10.3. Precipitation of microorganisms - biofilm formation.
Specialists who service reverse osmosis plants are constantly faced with such a phenomenon as the accumulation of some kind of mucus inside the membrane module, i.e. on the surface of the OO element and its holder. This is what lies on the surface ... The same mucus is located inside the OO membrane itself. A more correct name for this slime is biofilm , i.e. colonies of microorganisms fixed and developed on the surface of the membrane module.
We have already considered the process of biofilm formation in water supply systems in one of our publications, so here we should dwell on the features that are inherent in this process occurring on OO membranes. The biochemical effect of microorganisms on asymmetric semi-permeable OO membranes is considered to be more dangerous than the chemical destruction of membranes under the influence of oxidizing agents. Under certain conditions, biofilms can destroy the upper active layer of the membrane to its supporting layer, in which the pore size is commensurate with the size of bacteria. This is especially dangerous in the production of drinking water, since in this case pathogenic microbes and viruses from the source water can enter the filtrate (permeate).
The process of fixing microorganisms on the membrane surface is mainly determined by its properties: the material from which the membrane is made, the roughness of its surface, hydrophobicity and the surface charge of the membrane.
The design of helical OO membrane elements and the conditions on the membrane surface are ideal for the attachment, accumulation and growth of microorganisms. Why? First, the huge surface of the membrane; secondly, the height of the layer on the water-membrane interface is limited, and the layer itself is saturated with nutrients due to concentration polarization. Thirdly, in a narrow space of channels on turbulator grids separating membrane sheets, the water velocity is relatively low (about 0.1 m/s), and turbulence zones are limited. Finally, some polymeric materials, such as cellulose acetate, are a good breeding ground for microorganisms. This creates prerequisites for the development of colonies of microorganisms on the membrane surface, and their metabolic products can cause structural changes in the membrane polymer, especially in the structure of its thin active layer, which will lead to a deterioration in the characteristics of the desalination process.
In section 6.2 of this publication, we considered the fundamental design of a spiral wound reverse osmosis element. Let us briefly recall that in this construction ( see Fig.6.2 ) on the central pipe (pos.7), through which the filtrate is discharged, a “sandwich” is wound, consisting of two OO membranes (pos.4), turbulator meshes (pos.5) and a gasket for collecting permeate (pos.6) .
To create turbulence on the grid (pos.5), the movement of the liquid is carried out, as a rule, along the diagonal of the grid rhombus (see figure), therefore, small stagnant zones can form near each cross strut of the grid, where the growth of biological fouling begins. In this case, hydrodynamic forces will be the main mechanism for transporting microorganisms to the membrane surface. And in the absence of water movement (for example, with a simple OO-installation), cells can be transported directly to the membrane surface due to brownian motion or chemotaxis. The growth of biofouling will continue until the hydrodynamics of the flow change, i.e. the conditions of transportation and fixation of microorganisms will not change (for example, the presence of water hammer or a change in the composition of water).
This is the first step in the formation of a biofilm on the membrane surface. Next, the immobilization (fixation) of microorganisms on the membrane surface occurs due to the electrokinetic or hydrophobic interaction of the cell with the surface molecules of the membrane. After that, cell growth and reproduction begins both due to soluble nutrients in the source water and due to substances adsorbed on the membrane surface. This growth and reproduction of cells is accompanied by the release of an intercellular substance (polysaccharide), which anchors the cell to the surface, “clings” and fixes other cells to the substrate, and thereby stimulates microbial colonization of the membrane surface.
In addition, the resulting biofilm can act as a "trap" for suspended particles (they were discussed a little earlier), which, in turn, can quickly create dense deposits on the membrane.
There are a number of indicators that can change to help the operator determine that biofouling is the likely cause of a decline in reverse osmosis plant performance. These include:

  1. increase in pressure drop across the plant;
  2. decrease in water flow through the membranes (decrease in permeate productivity);
  3. decrease in the quality of purified water (increase in the specific conductivity of the permeate);
  4. the presence of slimy deposits on the inlet cartridge filters.

The number of genera and species of microorganisms present on the surface of OO membranes can be very diverse, and, in general, depends on the source of water supply, its organization and subsequent stages of pre-treatment before being fed to the OO membrane. Microorganisms present in the incoming source water may include bacteria, fungi, and yeasts. So, on the surface of the membrane, bacteria belonging to the genera are regularly found: Corynebacterium (lat. Сorynebacterium), pseudomonas (lat. Pseudomonas), actinomycetes (lat. Actinomyces), flavobacteria (lat. Flavobacterium), aeromonas (lat. Aeromonas), bacteria of the genus Arthrobacter and others. Of the fungi were found: penicilli (lat. Penicillium), mukora (lat. Mucor), trichoderma (lat. Trichoderma), fusariums ( Fusarium), aspergillus (lat. Aspergillus), etc. And from yeast: candida (lat. Candida); pichia (lat. Pichia), lipomycetes (lat. Lipomyces), yeast of the genus Ambrosiozyma etc. Most often, the genus Pseudomonas (lat. Pseudomonas), which refers to "good producers" of polysaccharides - the main component of mucus.
Typically, the total number of bacteria found on the surface of the OO membrane ranges between 106 and 108 cfu/cm 2 . But it is impossible to say in advance which of the genera and species will be present and prevail in the deposits on the OO membrane, even if the qualitative and quantitative microbiological composition of the source water is known. It is generally accepted that the fewer micro-organisms in the water before an RO installation, the less likely it is to biofoul. Therefore, usually for monitoring, the determination of the total microbial number (TMC) in the source water before reverse osmosis is widely practiced . And as a universal means of protecting reverse osmosis from biofouling, reliable preliminary treatment of source water is considered.
It turned out that the best way limiting the growth of microorganisms is both the effective removal of the microorganisms themselves and the nutrients that they use in the course of their life. Therefore, for the preliminary treatment of source water, processes such as water disinfection with biocides, proportional dosing of coagulants and flocculants, and multi-stage filtration are used: mechanical filtration, catalytic iron removal, adsorption purification, and, if necessary, softening. The same processes are used to remove suspended particles from the source water.
Finally, it should be noted that an important role in the prevention of biofouling and removal of biofilm during the operation of the OO unit is played by the processes of periodic chemical cleaning and disinfection of OO modules using chemical washing units. We will talk about this separately ...

10.4. Precipitation of sparingly soluble compounds.
In this article in section 5, devoted to concentration polarization, we have already indicated that as a result of this phenomenon, “... precipitation on the membrane surface of some sparingly soluble salts as a result of their concentration at the membrane surface».
What sparingly soluble compounds can precipitate on the membrane surface? To answer this question, let us turn to the quality indicators by which source water is certified, namely ionic balance of source water .
We have repeatedly pointed out that before designing a reverse osmosis system, a complete and accurate analysis of the source water must be performed. In addition to general indicators, such as: pH, turbidity, color, suspended solids content, permanganate oxidizability, alkalinity, total hardness, carbonate hardness, salinity (mineralization), contamination by microorganisms, the content of active and combined chlorine, etc., water analysis protocol must contain the name and concentration - of the following components in water:

Cations: mg/l mg-eq./l % Anions mg/l mg-eq./l %
Calcium Ca2+ Bicarbonates HCO 3 2-
Magnesium Mg 2+ Carbonates CO 3 2-
Sodium Na+ Sulphates SO 4 2-
Potassium K+ Chlorides Cl -
Iron Fe 2+ Fluorides F-
Iron Fe 3+ Nitrates NO 3 -
Manganese Mn 2+ Nitrites NO 2 -
Aluminum Al 3+ phosphates PO 4 3-
Ammonium NH4+ Borates (for boron)
Barium Ba 2+ Sulfides S 2-
Strontium Sr 2+ Silicon by SiO 2
Copper Cu 2+
Zinc Zn 2+
Sum of cations Ʃ 100% The sum of anions Ʃ 100%

Limits of detection of cations Ba 2+ andSr 2+ should be no more than 1 μg / l (1ppb) and not more than 1 mg/l (1ppm), respectively.

In this case, the total content of cations in water, expressed in mg-eq./l, should be equal to the total content of anions, expressed in mg-eq./l. The ionic balance of water converges only under this condition.
By combining the cations and anions present in the source water, and using the hint of Table 10.4.1, one can easily verify that in almost any water, the formation of sparingly soluble compounds is possible. The only question remains - will their concentration reach the limit at which these substances will begin to precipitate. The answer to it "lies on the surface" - the experience of operating reverse osmosis plants shows that situations arise when sparingly soluble salts are concentrated on OO membranes to a content above their solubility limit. A series of sparingly soluble salts was even compiled in order of decreasing problems with their deposits on the surface of membranes:

CaCO 3 > CaSO 4 >silicates> SrCO 3 > BaSO 4 > SrSO 4 > CaF 2 > CaSiO 3 > MgSiO 3 > Ca 3 (PO 4) 2 > Fe(HE) 2

Let's try to understand this series.
As a rule, all natural waters contain bicarbonates and carbonates, which for the most part determine the alkalinity of water or carbonate hardness. The process of formation of carbonates and bicarbonates is incorporated in the water cycle in nature: when precipitation falls on the ground, dissolution occurs in it carbon dioxide from the air and form carbonic acid ( H2CO3 ), while its concentration in water is ~ 0.05%:

H 2 O + CO 2 → H 2 CO 3

In an aqueous solution, carbonic acid dissociates in two stages:

H 2 CO 3 ↔ H + + HCO 3 ¯;
HCO3¯ ↔ H + + CO3 2 ¯

As it passes through the soil, "sour water" (a weak solution of carbonic acid) washes out calcium carbonate from earthen rocks, as a result of which hydrocarbonates are formed. The water of most natural springs is close to saturation with calcium carbonate. Depending on the pH of the water, calcium carbonate is in equilibrium with calcium bicarbonate and dissolved carbon dioxide:

CaCO 3 + H 2 O + CO 2 ↔ Ca 2+ + 2HCO 3 ¯

or simplified in ionic form:

CaCO 3 + H + ↔ Ca 2+ + HCO 3 ¯

It has been found that if the pH value is below 8.3, the bicarbonate alkalinity (and carbonate hardness) will be balanced by a certain amount of carbon dioxide dissolved in the water. At a pH greater than 8.3, bicarbonates (HCO 3 -) will turn into carbonates (CO 3 2-). Those. when the pH value decreases, the equilibrium in the equation can be shifted to the right, and vice versa.
Thus, when the initial water is concentrated in the near-membrane layer, the equilibrium in the above reaction equation begins to shift to the left (water is removed from the layer). In addition, part of the free carbon dioxide, together with water, also passes through the OO membrane into the permeate. In this case, the pH value in the concentrate increases. As a result, the carbon dioxide balance in the near-membrane layer of water shifts - an excess of carbonate ions is formed, which interact with calcium ions.
From the foregoing, it follows that in order to avoid precipitation of calcium carbonate, the pH value in the concentrate stream must be lower than the pH value at which calcium carbonate in the concentrate stream is in equilibrium with saturation calcium bicarbonate - pHs.
The difference between the pH value of the concentrate and the saturation pH value ( pH - pH s ) are called Langelier index (LSI - Langelier Saturation Index ) , the sign of which determines the carbonate stability of water and the possibility of calcium carbonate precipitation on the OO membrane. To prevent the formation of carbonate deposits on the membrane surface, the LSI index should always be negative. Those. when designing reverse osmosis plants for water with high alkalinity, it is necessary to use water pre-treatment methods that will help reduce the Langelier index, such as acidification (proportional dosing of the acid solution) and softening the source water or treating it with sedimentation inhibitors - dosing of anti-scaling agents. The operation of a reverse osmosis plant can be controlled by

AQUAFLOW RO reverse osmosis systems are used for water desalination and desalination. They are used in technological processes requiring reduction general content salts to the required parameters.

The principle of water purification by reverse osmosis

Reverse osmosis is a process based on increasing the pressure level of water to values ​​from 10 to 65 bar, allowing the movement of water molecules through a semi-permeable membrane. Salts and heavy metals, microorganisms and organic compounds dissolved in water will not pass through the filters and will be removed in the form of a concentrate in drainage system. Practice shows that the use of reverse osmosis systems allows you to clean 80-99.7% of the salts contained in the water. This indicator also depends on the type of cleaning membranes used, the scheme and design of the equipment, and the composition of the water.

After passing the reverse osmosis filters, the water can be used in steam boilers(helps to increase efficiency by reducing the number of purges and prevents corrosion), in the production of beverages, in various industries (medical, electronic, metallurgical, engineering).

With reverse osmosis, the breakdown of substances dissolved in water is carried out at the molecular level. As a result, contaminants accumulate on one side of the filter membrane, and purified water collects on the other.

Thus the work industrial systems reverse osmosis provides a significantly higher level of water purification than installations using traditional methods of purification and filtration of mechanical particles. They are also superior to devices that adsorb substances using activated carbon.

Reverse osmosis membranes and filters

The latest models of industrial reverse osmosis water filters are made from various materials. The most widely used products are made of polyamide. They are made asymmetrical with a two-layer construction. The actual reverse osmosis layer is applied to the substrate, its thickness can be from 5 to 7 microns. The thickness of the substrate is about 100-200 µm. This design makes it possible to guarantee the efficient operation of the filter at high pressure.

Such a membrane in a reverse osmosis treatment plant is placed working surface to the water to be purified. The treated water (permeate) entering through the pores of the filter is removed from the membrane space.

Design features of reverse osmosis membranes

Structurally, the membranes are a water filter, in which mesh dividers are rolled around the central collection manifold. Two such membrane sheets are glued around the perimeter. Several membrane envelopes are inserted into prefabricated manifold one of the unglued sides. Between envelopes mesh delimiters are located. The entire reverse osmosis system is coiled, in which water moves from one element to another, penetrates through the membranes and is discharged through the inside of the envelopes into the central collector. Impurities in the form of a concentrate are removed from the opposite side of the membrane element.

When choosing a type industrial plant should take into account the nature of dissolved in water chemical elements. The fact is that when treating water with devices with the same reverse osmosis filters, multivalent ions are retained better than monovalent ones. The order of the degree of ion retention (in ascending order) corresponds to the series of hydration energy distribution:

H+< NO3- < I- < Br- < Cl- < K+ < F- < Na+ < S042- < Ba2+ < Ca2+ < Mg2+ < Cd2+ < Zn2+ < Al3+.

All reverse osmosis units are designed to operate under the following conditions:

  • incoming water temperature - +10 °С;
  • iron content - no more than 0.05 mg/l;
  • lack of free chlorine;
  • SDI level - no more than 3;
  • salinity level - 1 500 mg/l.

Contents of delivery

LLC "VODEKO" at the best prices offers to purchase reverse osmosis systems "AQUAFLOW RO" of various models.

Household reverse osmosis systems.

Commercial reverse osmosis systems

Industrial reverse osmosis systems of the RO series are delivered completely ready to work. All equipment is factory assembled and tested. The units are equipped with a set of protective automation, a controller-based control system, and the necessary devices for easy setup and operation. Equipment performance data may vary depending on the type of membranes used, water parameters and filter features.




Model Flows, m 3 / h

Ref / concentrate / permeate

Energy consumption, kW Number of membranes, pcs. Dimensions LxWxH, m Dimensions CIP DxH, m Weight, kg
RO-40-0.25 0,33 / 0,08 / 0,25 1,5 1 0.75 x 0.43 x 1.65 0.47 x 0.85 120
RO-40-0.5 0,67 / 0,17 / 0,5 2 135
RO-40-0.75 1,0 / 0,25 / 0,75 3 150
RO-40-1.0 1,33 / 0,33 / 1,0 2,2 4 165
RO-40-1.5 2 / 0,5 / 1,5 6 200
RO-40-2.0 2,67 / 0,67 / 2,0 4 8 0.91 x 0.47 x 1.65 210

Technology system:


1 c.u. = 1 US dollar at the exchange rate of the Central Bank of the Russian Federation on the date of payment.

Industrial reverse osmosis systems

This equipment is needed in order to reduce the mineralization of water, remove impurities from it (sodium, boron, fluorine, hardness salts, sulfates, nitrates, etc.). The main requirement for the water supplied to the installation is the absence of microbiological contamination in it.

Advantages of osmosis produced by VODEKO LLC:

  1. Management by means of the touch LCD display: the menu in Russian. All time intervals, pressure settings, electrical conductivity can be adjusted by the operator.
  2. Only proven and high-quality components from leading world manufacturers are used. The unit frame is made of AISI 304 stainless steel.
  3. Comprehensive equipment provides ease of maintenance and long life cycle equipment.

We provide a guarantee for all sold equipment.

Technical data of standard AQUAFLOW plantsRO

Type

Productivity, m3/h **

Type/Number of membranes. elements

Overall dimensions, no more than, L x W x H, mm **

N, kW

Weight, kg

RO 40-0.25

0,25

4040 / 1

1500 x 1500 x 1750

1,2

200

RO 40-0.5

0,5

4040 / 2

1500 x 1500 x 1750

2,0

220

RO 40-0.75

0,75

4040 / 3

1500 x 1500 x 1750

2,2

240

RO 40-1

1,0

4040 / 4

1500 x 1500 x 1750

2,5

260

RO 80-2

2,0

8040 / 2

2500 x 1500 x 1750

3,5

500

RO 80-4

4,0

8040 / 4

2500 x 1500 x 1750

5,0

760

RO 80-5

5,0

8040 / 5

2500 x 1500 x 1750

6,0

825

RO 80-7

7,0

8040 / 7

4500 x 1600 x 1750

7,5

910

RO 80-8

8,0

8040 / 8

4500 x 1600 x 1750

7,5

1150

RO 80-9

9,0

8040 / 9

4500 x 1600 x 1750

11,0

1250

RO 80-10

10,0

8040 / 10

5500 x 1750 x 1800

11,0

1300

RO 80-12

12,0

8040 / 12

5500 x 1750 x 1800

11,0

1400

RO 80-15

15,0

8040 / 15

5500 x 1750 x 1800

15,0

1550

RO 80-18

NPC PromVodOchistka makes reverse osmosis plants of any capacity from 0.25 m3/hour.
The site provides information about the most requested installations. If you did not find a reverse osmosis unit of the performance you need, or call us (8-800-1000-980) - a specialist will advise you on the installation cost and production time.

Equipment Models

Purpose and scope of reverse osmosis technology.

Reverse osmosis is one of the most promising and widely used methods of water purification and preparation. The reverse osmosis unit is capable of removing particles with sizes of 0.001-0.0001 microns from water. This range includes hardness salts, sulfates, nitrates, sodium ions, small molecules, dyes. For more efficient operation, it is recommended to use preliminary cleaning steps ( mechanical cleaning and micro-, ultra- or nanofiltration) to remove larger particles.

reverse osmosis system has proven itself in many areas:

  • reduction of salt content in the waters of open and underground sources;
  • desalination of sea waters;
  • obtaining solutions of a certain concentration for technological needs;
  • preparation of water for heat and power needs (boiler rooms, boiler rooms);
  • final stage of wastewater treatment in a closed water cycle;
  • use in water disinfection systems.

The composition of reverse osmosis systems of the PVO-RO series:

Basic equipment:

Equipment

Mechanical filter 5 microns;

Reverse osmosis membranes in pressure vessels;

Protection of the pump from running in dry running mode;

High pressure centrifugal pump with cast iron base;

Stainless steel high pressure centrifugal pump;

Frequency regulation of pumping equipment;

Control of the frequency converter by constant speed of rotation of the pump shaft;

Control of the frequency converter according to the readings of the pressure sensor;

System of a delay and smooth inclusion of the pump;

Visual flow meters on the permeate and concentrate lines;

Analog flow meters on permeate and concentrate lines;

Working pipelines made of PVC-U / polypropylene;

Working pipelines made of stainless steel;

Powder coated steel frame;

Stainless steel frame;

Control cabinet with relay control and control panel;

Control cabinet with controller and control panel;

Operating parameters adjustment system;

Hydrofilled inlet and working pressure gauges;

Antiscalant dosing system;

Digital permeate conductivity meter;

Discharge of the first portion of the permeate into the drain;

System of automatic direct flushing of membranes;

Membrane chemical flushing system with tank, flushing pump and control panel.

Options (on request):

Equipment
01

Advanced control system based on industrial controller;

System of preliminary preparation of initial water before installation of the return osmosis;

Dispatching of the equipment control process with the output to the computer of a process engineer or operator;

Tanks of clean and/or raw water;

Additional pumping equipment;

Redundancy of the main equipment;

Extended warranty - 5 years.

How a reverse osmosis system works.

Reverse osmosis belongs to the group of baromembrane technologies. driving force process is the pressure difference on both sides of a semi-permeable porous membrane.

Membrane materials are usually cellulose acetate and polyamide films or hollow fibers. Structurally, filter elements can be of two types:

  • roll;
  • hollow fiber.

Due to the features internal structure modules, the input stream is divided into parts:

  • permeate - purified water that has passed through the membrane;

concentrate - dirty water with a high content of impurities that have not passed through the pores of the membrane.

Filtration occurs through the pores of the material. The filtered flow contains water molecules, low molecular weight compounds and ions smaller than water molecules. All other components of the solution, both mechanical (individual molecules, viruses) and dissolved (metal ions, salts), are retained.


During operation, a large amount of contaminants gradually accumulate on the surface and in the pores of the membrane. This sediment reduces the performance of the plant. You can restore working capacity by conducting a regeneration (washing) cycle.

Most often, surface cleaning is performed by backwashing with a stream of water or blowing compressed air. In some cases, to increase the interval between cleanings, certain reagents are added to the wastewater stream to prevent the formation of chemical precipitation.


Complete set of reverse osmosis plants.

Depending on the composition of the incoming water and the conditions of the process, the composition of reverse osmosis plants may vary somewhat. The standard basic package includes the following functional elements:

  • fine pre-filter - performs preliminary preparation of the water flow, removing solid particles up to 5 microns in size;
  • filtration block - serves for mounting membrane modules inside which the filtration process is carried out;
  • pumping equipment - allows you to provide the required pressure drop for the process;
  • installation piping
  • control and measuring and control fittings - performs automatic control of the installation;
  • flushing block - flushes the surface of the membranes.

Components of a reverse osmosis plant on the example of PVO-RO-1

Benefits of reverse osmosis filters

  • the highest level of purification among all filter technologies;
  • during operation, the use of additional reagents is not required;
  • compact layout of equipment;
  • a wide range of standard models covering a wide range of performance;
  • ease of operation and maintenance;
  • high degree of automation of the installation;
  • the possibility of embedding in global automated control systems for the processes of water purification and preparation;
  • a modular system that allows you to increase the performance of a standard installation by adding additional filter elements;
  • use of corrosion-resistant materials for fittings and piping installation.

Brief information. Features of reverse osmosis systems.

Plant layout options

Efficient operation of a reverse osmosis plant without the use of preliminary purification stages is very problematic. The filter surface of the membranes will clog very quickly and most of the working time will be spent flushing the equipment. Ultimately, this will lead to a rapid failure of the membrane elements.

Depending on the operating conditions, the layout of the technological stages of the water treatment process using reverse osmosis plants may vary slightly:

  • option 1:
    • rough mechanical cleaning;
    • reverse osmosis.

Used for cleaning groundwater coming directly from the well. Inlet water is characterized by high mineralization

  • option 2:
    • rough mechanical cleaning;
    • mechanical cleaning through a layer of filter media;
    • reverse osmosis.

It is used in the treatment of waters with a high content of suspended solids, iron, high color. Most often, water from surface open water intakes has such characteristics.

  • option 3:
    • rough mechanical cleaning;
    • water softening;
    • filtration through a layer of sorbent;
    • reverse osmosis.

Main purpose processing natural waters containing a large amount of hardness salts.

  • option 4:
    • rough mechanical cleaning;
    • ultrafiltration;
    • filtration through a layer of sorbent;
    • reverse osmosis.

The most versatile scheme that allows you to process natural and wastewater with a wide range of contaminants.

Reverse osmosis units offered by NPC PromVodOchistka ensure stable operation and highest quality water purification. This is confirmed by the results of the already implemented and successfully operated facilities.

At all stages, from design and assembly, to the stages of installation, commissioning and operation, quality control of decisions, materials and equipment is carried out. When contacting us, highly qualified specialists will help you find a solution for any situation.

The scope of the company's activities includes the design of the technological process of cleaning, selection of equipment, installation, commissioning and service maintenance in any corner of Russia. Each stage of work is carried out in strict accordance with the ISO 9001 quality system standards.

NPC PromVodOchistka makes reverse osmosis plants of any capacity from 0.25 m3/hour. The site provides information about the most requested installations. If you did not find a reverse osmosis unit of the performance you need, or call us (8-800-1000-980) - a specialist will advise you on the installation cost and production time.